• Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
  • Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
  • Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
  • Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
  • Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
  • Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System

Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System

Task: Program
Mathematical Model: Linear
Signal: Discrete
Condition: New
Customized: Customized
Material: Aluminum Alloy
Samples:
US$ 10000/Set 1 Set(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Typical Wiring
  • Products Show
  • Display Demo
  • Application
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
BCM101
Product Name
Scada Monitoring System
Cabinet
Array Cabinet
Application
Power Disribution System
Display
7" TFT Screan
Connection
RS485 Interface
Current Trsanformer
Plug-in Type
Relay Output
Available
Protocol
Modbus-RTU
Installation Type
DIN Rail 35mm
Power
DC24
Transport Package
Each PCS in Inner Box with Air Bag, 16PCS in Maste
Specification
96*96mm
Trademark
ELECNOVA
Origin
China
HS Code
9030899090

Product Description

Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring SystemProduct Name:  Energy power distribution software supervising individual module industrial control scada monitoring system

Product Description

Elecnova BCM series precision power distribution monitoring system is use for the supervising of power parametres for  the DC array cabinet. It measures the voltage, currency, power harmoics and all the ON/OFF status of the circurt breakers both for the incoming line and feeder. There is a 7" colorful TFT screen for display the real time data which could be installed on the cabinet, it also provide the Ethernet interface for connecting with the other systems.  

Product Name
Energy power distribution software supervising individual module extend PC/screen industrial control scada monitoring system
Protocol
Modbus-RTU
Power
DC 24V
Accuracy
0.1% CT
Metering chip set
TI(Texas Instruments)
Installation type
35mm
Display
7" TFT screen/PC screen
Warranty
2 years
Typical Wiring
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Products Show
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Module No: 
BCM101-M2, Incoming line Module
Accuracy
U/I 0.2, P/Q/PF: 0.5
 
Signal input
Voltage:3 phase 3*220/380V,                              1 phase AC 220V
Currency: AC5A/AC1A
Frequency
45~65Hz, Accuracy: ±0.01Hz
Switching  Value
Type: 4 Circurt, Dry contact
Withstand voltage: 2kV AC
 
Relay  output
Capacity: 2 Circurt, AC250V/5A DC                          30V/3A
Withstand voltage: 2kV AC
Communication
2 circurt RS485, Modbus-RTU,           1 circurt RJ45, Modbus-TCP(option)
Power
DC:24V
Installation 
126*133*50mm,Din rail 35mm
 
 
Module
BCM-101-S, Feeder monitoring
Accuracy
U/I 0.2, P/Q/PF: 0.5
Signal input
Voltage: 1 phase AC 220V
                Overload: 1.2Un continuing
                                   2Un/1 min instant
Currency: 100A(External CT)
                  Overlaod: 1.2ln continuing
                                     10ln/5s
Frequency
45~65Hz, Accuracy: ±0.1Hz
Switching Value
30 circurt, voltage value determines the breaker Close/Open , Voltage>120 Close, Voltagge <110V Open
Wire contact
2
Installation
126*125*50mm,Din rail 35mm
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
 
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
 
Module
BCM101K, Switching Value(Option)
Circurt
60 Circurt, Wet contact
Input Voltage
DC24V±2V
Inslation
2kV
Wire contact
2
Installation
126*133*50mm, Din rail 35mm
 
 
Module
Current Transformer Module
Rated Value
SHI-BCT50 II: 5(50)A, SHI-BCT100II: 5(100)A
Accuracy
0.1
Overload
1.2ln continuing
10ln/5S, instant
Consumption
≤0.2VA(per phase)
Inslation withstand voltage
4000V/min
Installation
5(50A): 26*33.5*11.5mm,φ8.9
5(100A): 45*52.5*17.5mm,φ19
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
 
 
Display
BCM101-HMI
Monitor
7" TFT LCD screen, 800*480 definition
Interface
RS485: Modbus-RTU protocol
USD: USB 2.0
Power
Working range: DC: (24±20%)V
Consumption: ≤5W
Installation
215*215mm, Panel mount
 
 
Module No
BCM101-P, Power module
Input  voltage range
AV180V~260V,DC220V~370
Output Value
DC 24V
Output Power
≤20W(25°C)
Efficiency
>75%
Inslation Intensity
AC 2kV/min
Installation
36*90*63.5mm, Din rail 35mm
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Display Demo
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Application
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System

 

Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System

 

 

Company Profile

 

Energy Power Distribution Software Supervising Individual Module Industrial Control Scada Monitoring System
FAQ

Q: Are you trading company or manufacturer ?
A: We are factory located in Jiangyin Jiangsu Province.



Q: Does your company provide customized manufacturing?
A: We provide OEM/ODM service to our customers. Our experienced R&D team will give our customer solution in a high efficiency way.



Q: How long is your delivery time?
A: 3-5 working days for the items were in stock, 15-21days for the items out of stock.



Q: Do you provide samples? Is it free or extra ?
A: You need to pay for the sample and cover the freight as well.



Q: What is your terms of payment ?
A: Order amount less than $3000, 100% paid before shipment, order amount more than $3000,30% as deposit, 70% before shipment, or by negotiated for the both parties.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
520
Year of Establishment
1998-01-15