Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction

Product Details
Customization: Available
Certification: ISO9001
Protection: Anti-static
Still deciding? Get samples of US$ 3500/Set
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
520
Year of Establishment
1998-01-15
  • Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
  • Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
  • Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
  • Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
  • Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
  • Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
Find Similar Products
  • Overview
  • Product Description
  • Technical Specifications
  • Project Case
  • Model Selection
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
SFR-SVG
Installation
Hanging
Color
Black
Response Time
≤5ms
Frequency
50-65Hz
Function
Harmonic Management
Delivery Time
7-15days
Standard
GB/T7251-2005
Transport Package
Wooden Box
Specification
510*218*694mm
Trademark
ELECNOVA
Origin
China
HS Code
9030899090
Production Capacity
20000PCS/Per Month

Product Description

Reactive Power Automatic Compensation Module 200 kVA Power Factor CorrectionReactive power automatic compensation module 200 kva power factor correction
The principle of the SVG is very similar to that of Active Power Filter, as demonstrated in the picture below. When the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. SFR-SVG is also capable of correcting load imbalance.

Product Description
Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
Application
Data centers
UPS systems
Renewable power generation
(e.g. photovoltaics and wind turbines)
Industrial production machines
Electrical welding systems
Plastic industry machinery
(e.g. extruders, injection molders)

Reactive Power Automatic Compensation Module 200 kVA Power Factor CorrectionReactive Power Automatic Compensation Module 200 kVA Power Factor Correction

Technical Specifications

 

 

 
Function
Technical parameters
Wall mounted SFR-SVG-(30~50)/B
Rack mounted SFR-SVG-(30~200)/M
Cabinet type SFR-SVG-(100~500)/G


Electrical
characteristics
Rated voltage(V)
AC380V±15%, AC690V±15%
Working frequency(Hz)
50Hz±5%
Rated compensation capacity(KVA)
30
50
30       50
75       100
150     200
100~500
Scope of reactive adjustment
Continuously adjustable from rated induced to rated capacitive
Response time
5ms
Loss of active power
<3% rated module power
Over-load capability
120%
Multi-set running mode
Parallel running
Mean time between failures
≥100,000hours


Local protection
Switching frequency
Average 10kHz
Control algorithm
compensation algorithm of screening vector of frequency domain possessing self-adaptation capability
Controller
Digital signal processor(DSP)
Communicationcapability
Adopting Modbus remote communication protocol,communication interface RS485/232 and CAN bus
Control connection
Optical fiber or electrical connection


Structural characteristics
W x H x D(mm)
510 x 218 x 694
340 x 629 x 709
Refer to capacity of cabinet
Protection grade
IP21 orcustomized according to the user' s demand
Color
RAL7035(light gray),
Cooling mode
Forced air cooling
Overall structure
Floor type
Installation mode
Indoor installation; optional fixing modes and optional cable incoming modes


Environmental conditions
Environmental temperature
-10~40ºC
Storage temperature
-40~65ºC
Relative humidity
5%-95%, no condensation
Altitude
≤1000m,1000-4000;according to national standard GB/T3859.2, for every increased 100m, the power is reduced by 1%
Electromagnetic
compatibility
Conforming to GB/T7250-2005

 

Project Case
Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
Reactive Power Automatic Compensation Module 200 kVA Power Factor Correction
Model Selection
Transformer Capacity(kVA)
Three-phase Four-wire
Three-phase Three-wire
200
SFR-SVG4-100/0.4 X 1
SFR-SVG3-100/0.4 X 1
250/315
SFR-SVG4-100/0.4 X 1
SFR-SVG3-100/0.4 X 1
400
SFR-SVG4-150/0.4 X 1
SFR-SVG3-200/0.4 X 1
500/630
SFR-SVG4-200/0.4 X 1
SFR-SVG3-300/0.4 X 1
800
SFR-SVG4-250/0.4 X 1
SFR-SVG3-400/0.4 X 1
1000
SFR-SVG4-300/0.4 X 1
SFR-SVG3-500/0.4 X 1
1250
SFR-SVG4-400/0.4 X 1
SFR-SVG3-300/0.4 X 2
1600
SFR-SVG4-250/0.4 X 2
SFR-SVG3-400/0.4 X 2
2000
SFR-SVG4-300/0.4 X 2
SFR-SVG3-500/0.4 X 2
2500
SFR-SVG4-400/0.4
SFR-SVG3-400/0.4 X 3
Company Profile

Reactive Power Automatic Compensation Module 200 kVA Power Factor CorrectionReactive Power Automatic Compensation Module 200 kVA Power Factor CorrectionReactive Power Automatic Compensation Module 200 kVA Power Factor CorrectionReactive Power Automatic Compensation Module 200 kVA Power Factor Correction

FAQ

Q: Are you trading company or manufacturer ?
A: We are factory located in Jiangyin Jiangsu Province.



Q: Does your company provide customized manufacturing?
A: We provide OEM/ODM service to our customers. Our experienced R&D team will give our customer solution in a high efficiency way.



Q: How long is your delivery time?
A: 3-5 working days for the items were in stock, 15-21days for the items out of stock.



Q: Do you provide samples ? Is it free or extra ?
A: You need to pay for the sample and cover the freight as well.



Q: What is your terms of payment ?
A: Order amount less than $3000, 100% paid before shipment, order amount more than $3000,30% as deposit, 70% before shipment, or by negotiated for the both parties.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier